Connectors for sheet pile wall structures
Corner connectors, T connectors, cross connectors, weld-on connectors
Connectors for pipe pile steel walls
Pipe spacing ~63 mm
Steel thickness 12 mm
Also suitable for Ball + Socket sheet piles
Pipe spacing ~64 mm
For pipe pile steel walls using DTH driving method.
We recommend connectors with a minimum tensile strength of 3,000 kN/m.
Steel thickness 12 mm
Pipe spacing ~75 mm
Steel thickness 12 mm
Also suitable for Ball + Socket sheet piles
Pipe spacing ~100 mm
Steel thickness 12 mm
Also suitable for Ball + Socket sheet piles
Steel thickness 10 mm
Pipe spacing ~130 mm
Steel thickness 12 mm
Also suitable for Ball + Socket sheet piles
Pipe spacing ~180 mm
Steel thickness 10 mm
Steel thickness 12 mm
Steel thickness 12 mm
Also suitable for Ball + Socket sheet piles
Steel thickness 12 mm
Also suitable for Ball + Socket sheet piles
Steel thickness 12 mm, connector with very high tensile strength
Steel thickness 16 mm
Pipe spacing ~230 mm
Steel thickness 12 mm
Also suitable for Ball + Socket sheet piles
Pipe spacing ~248 mm
Steel thickness 12 mm
Pipe spacing ~250 mm
Steel thickness 12 mm, connectors with high deformation capacity
Pipe spacing ~300 mm
Steel thickness 12 mm, connector with very high tensile strength
Steel thickness 16 mm
Pipe spacing ~310 mm
Steel thickness 12 mm
MF63
Steel grade: S355J2
Steel thickness: 12 mm
Standard lengths: 8 m, 11.8 m
Weight M35: 4.76 kg/m
Weight F28: 10.7 kg/m
Max. tensile strength:
2552 kN/m (FEM)
PDF Data sheet
DWG M35
DWG F28
Request this connector
MF64
Steel grade: S355J2
Steel thickness: 12 mm
Standard lengths: 8 m, 11.8 m
Weight M22: 3.42 kg/m
Weight F40: 14.28 kg/m
Max. tensile strength: 3419 kN/m
PDF Test report
PDF Data sheet
DWG M22
DWG F40
Request this connector
MF64-IC
Steel grade: S355J2
Steel thickness: 10 / 12 mm
Standard lengths: 8 m, 11.8 m
Weight M22: 3.42 kg/m
Weight F40-IC: 13.55 kg/m
Max. tensile strength: 3164 kN/m
PDF Data sheet
DWG M22
DWG F40-IC
Request this connector
MF75
Steel grade: S355J2
Steel thickness: 12 mm
Standard lengths: 8 m, 11.8 m
Weight M35: 4.76 kg/m
Weight F40: 14.28 kg/m
Max. tensile strength: 3419 kN/m
PDF Test report
PDF Data sheet
DWG M35
DWG F40
Request this connector
MF100
Steel grade: S355J2
Steel thickness: 12 mm
Standard lengths: 8 m, 11.8 m
Weight M60: 6.9 kg/m
Weight F40: 14.28 kg/m
Max. tensile strength: 3419 kN/m
PDF Test report
PDF Data sheet
DWG M60
DWG F40
Request this connector
LPB100-10
Steel grade: S355J2
Steel thickness: 10 mm
Standard lengths: 8 m, 11.8 m
Weight: 9.9 kg/m
PDF Data sheet
DWG
Request this connector
MF130
Steel grade: S355J2
Steel thickness: 12 mm
Standard lengths: 8 m, 11.8 m
Weight M90: 9.76 kg/m
Weight F40: 14.28 kg/m
Max. tensile strength: 3199 kN/m
PDF Test report
PDF Data sheet
DWG M90
DWG F40
Request this connector
LPB180-10
Steel grades: S355J2, S430GP
Steel thickness: 10 mm
Standard lengths: 8 m, 11.8 m
Weight: 12.84 kg/m
PDF Data sheet
DWG
Request this connector
LPB180-12
Steel grade: S355J2
Steel thickness: 12 mm
Standard lengths: 8 m, 11,8 m
Weight: 14,5 kg/m
Max. tensile strength: 1.502 kN/m
PDF Test report
PDF Data sheet
DWG
Request this connector
MF180a
Steel grade: S355J2
Steel thickness: 12 mm
Standard lengths: 8 m, 11.8 m
Weight M140: 14.7 kg/m
Weight F40: 14.28 kg/m
Max. tensile strength: 3419 kN/m
PDF Data sheet
DWG M140
DWG F40
Request this connector
MF180b
Steel grade: S355J2
Steel thickness: 12 mm
Standard lengths: 8 m, 11.8 m
Weight M90: 9.76 kg/m
Weight F90: 18.42 kg/m
Max. tensile strength: 2128 kN/m
PDF Data sheet
DWG M90
DWG F90
Request this connector
FD180
Steel grade: S355J2
Steel thickness: 12 mm
Standard lengths: 8 m, 11.8 m
Weight: 17.42 kg/m
Max. tensile strength: 5843 kN/m
Product on order only.
PDF Test report
PDF Data sheet
DWG FD180-12
Request this connector
LPB180-16
Steel grade: S355J2
Steel thickness: 16 mm
Standard lengths: 8 m, 11.8 m
Weight: 22.4 kg/m
Max tensile strength:
Please see LPB300-16
PDF Data sheet
DWG
Request this connector
MF230
Steel grade: S355J2
Steel thickness: 12 mm
Standard lengths: 8 m, 11.8 m
Weight M140: 14.77 kg/m
Weight F90: 18.42 kg/m
Max. tensile strength: 2128 kN/m
PDF Data sheet
DWG M140
DWG F90
Request this connector
LPB248-12
Steel grade: S355J2
Steel thickness: 12 mm
Standard lengths: 8 m, 11.8 m
Weight: 18.26 kg/m
Max. tensile strength: ~1500 kN/m
Product on order only.
PDF Data sheet
DWG
Request this connector
LZ250-12-A, LZ250-12-B
Steel grade: S355J2
Steel thickness: 12 mm
Standard lengths: 8 m, 11.8 m
Weight: 19.48 kg/m each
Max. tensile strength: 1200 kN/m
Pressure load: 800 kN/m
Deformation path: ±50 mm
Product on order only.
PDF FEM Simulation
PDF Data sheet
DWG LZ250-12-A
DWG LZ250-12-B
Request this connector
FD300-12
Steel grade: S355J2
Steel thickness: 12 mm
Standard length: 13.8 m
Weight: 21.4 kg/m
Max. tensile strength: 6312 kN/m
PDF Test report
PDF Data sheet
DWG
Request this connector
LPB300-16
Steel grade: S355J2
Steel thickness: 16 mm
Standard lengths: 8 m, 11.8 m
Weight: 29.65 kg/m
Max. tensile strength: 1828 kN/m
PDF Test report
PDF Data sheet
DWG
Request this connector
MDF310
Steel grade M140: S355J2
Steel grade DF: S430
Steel thickness: 12 mm
Standard lengths: 8 m, 11.8 m
Weight M140: 14.77 kg/m
Weight DF: 14.62 kg/m
Max. tensile strength:
3271 kN/m (FEM)
PDF Data sheet
PDF FEM Simulation
DWG M140
DWG DF
Request this connector
Technical data / disclaimer
SteelWall connectors generally comply with the European standards and are manufactured by certified steel processing companies.
All figures are approximate and may vary. Bar twists are possible up to 2 mm per meter. Tolerance of steel thickness ±1 mm.
Length tolerance up to ±200 mm. Degree details refer to the connector bar axes. Welding base of LPB and FD clutches can be straight or bevelled. We reserve the right to make technical changes. We refer to DIN EN 12063. Please check the sheet pile interlocks with a physical sample section of the desired connector for compatibility.
2024-Jan-10. Copyright by SteelWall ISH GmbH. Connectors designed by Richard Heindl.