Connectors for steel sheet pile walls

Connectors for sheet pile wall structures

Corners, T-corners, crosses, junctions, weld-ons

SteelWall connectors for H pile combined steel walls

with Larssen sheet piles  /

with Ball & Socket sheet piles

For Larssen U sheet piles

For Larssen Hat-type sheet piles

For Larssen Z sheet piles

For Larssen U sheet piles

For Larssen Z sheet piles

For Larssen U sheet piles

For Larssen Z sheet piles

For Ball & Socket sheet piles

For Ball & Socket sheet piles

LPB100-9A

Steel grades: S355, S430

Steel thickness: 9 mm

Length: 11.80 m, 18 m

Weight: 9.05 kg/m

Max. tensile strength: 912 kN/m

PDF Folder LPB Series

DWG

Request this connector

LPB100-10

Steel grades: S355, S430

Steel thickness: 10 mm

Length: 11.8 m, 18 m

Weight: 9.86 kg/m

Max. tensile strength: 980 kN/m

PDF Folder LPB Series

DWG

Request this connector

LPB180-10

Steel grades: S355, S430

Steel thickness: 10 mm

Length: 11.8 m, 18 m

Weight: 12.94 kg/m

Max. tensile strength: 1,026 kN/m

PDF Folder LPB Series

DWG

Request this connector

MF75 (M35 + F40)

Steel grade: S355J2

Steel thickness: 12 mm

Length: 8 m, 11,8 m

Weight M35: 4.76 kg/m

Weight F40: 14.28 kg/m

MF75 max. tensile strength:

3.419 kN/m

PDF Data sheet

DWG M35

DWG F40

Request this connector

MF180 (M90 + F90)

Steel grade:  S355J2

Steel thickness:  12 mm

Length:  8 m, 11,8 m

Weight M90:  9.76 kg/m

Weight F90:  18.42 kg/m

 

PDF Data sheet

DWG M90

DWG F90

Request this connector

Test report

PDF: Tensile and twist out tests

Connectors

overview 2022

Technical data / disclaimer

SteelWall connectors generally comply with the European standards and are manufactured by certified steel processing companies.

All figures are approximate and may vary. Bar twists are possible up to 2 mm per meter. Tolerance of steel thickness ±1 mm.

Length tolerance up to ±200 mm. Degree details refer to the connector bar axes. Welding base of LPB and FD clutches can be straight or bevelled. We reserve the right to make technical changes. We refer to DIN EN 12063. Please check the sheet pile interlocks with a physical sample section of the desired connector for compatibility.

 

2022-Jan.-16. Copyright by SteelWall ISH GmbH. Connectors designed by Richard Heindl.