Start

Gallery

Download DWG files

About us

Sealant

Contact

Connectors for steel sheet pile walls

Connectors for sheet pile wall structures

Corner connectors, T connectors, cross connectors, weld-on connectors

Connectors for H pile steel walls

Spacing of H piles ~63 mm

Steel thickness 12 mm

Also suitable for Ball + Socket sheet piles

Spacing of H piles ~75 mm

Steel thickness 12 mm

Also suitable for Ball + Socket sheet piles

Spacing of H piles ~100 mm

Steel thickness 12 mm

Also suitable for Ball + Socket sheet piles

Spacing of H piles ~130 mm

Steel thickness 12 mm

Also suitable for Ball + Socket sheet piles

Spacing of H piles ~180 mm

Steel thickness 12 mm

Also suitable for Ball + Socket sheet piles

Steel thickness 12 mm

Also suitable for Ball + Socket sheet piles

Steel thickness 12 mm, connector with very high tensile strength

Spacing of H piles ~230 mm

Steel thickness 12 mm

Also suitable for Ball + Socket sheet piles

Spacing of H piles ~300 mm

Steel thickness 12 mm, connector with very high tensile strength

Spacing of H piles ~310 mm

Steel thickness 12 mm

MF63

Steel grade: S355J2

Steel thickness: 12 mm

Standard lengths: 8 m, 11.8 m

Weight M35: 4.76 kg/m

Weight F28: 10.7 kg/m

Max. tensile strength:

2552 kN/m (FEM)

PDF Data sheet

DWG M35

DWG F28

Request this connector

MF75

Steel grade: S355J2

Steel thickness: 12 mm

Standard lengths: 8 m, 11.8 m

Weight M35: 4.76 kg/m

Weight F40: 14.28 kg/m

Max. tensile strength: 3419 kN/m

PDF Test report

PDF Data sheet

DWG M35

DWG F40

Request this connector

MF100

Steel grade: S355J2

Steel thickness: 12 mm

Standard lengths: 8 m, 11.8 m

Weight M60:  6.9 kg/m

Weight F40:  14.28 kg/m

Max. tensile strength: 3419 kN/m

PDF Test report

PDF Data sheet

DWG M60

DWG F40

Request this connector

MF130

Steel grade: S355J2

Steel thickness: 12 mm

Standard lengths: 8 m, 11.8 m

Weight M90: 9.76 kg/m

Weight F40: 14.28 kg/m

Max. tensile strength: 3199 kN/m

PDF Test report

PDF Data sheet

DWG M90

DWG F40

Request this connector

MF180a

Steel grade: S355J2

Steel thickness: 12 mm

Standard lengths: 8 m, 11.8 m

Weight M140: 14.77 kg/m

Weight F40: 14.28 kg/m

Max. tensile strength: 3419 kN/m

PDF Data sheet

DWG M140

DWG F40

Request this connector

MF180b

Steel grade: S355J2

Steel thickness: 12 mm

Standard lengths: 8 m, 11.8 m

Weight M90: 9.76 kg/m

Weight F90: 18.42 kg/m

Max. tensile strength: 2128 kN/m

PDF Data sheet

DWG M90

DWG F90

Request this connector

FD180-12

Steel grade: S355J2

Steel thickness: 12 mm

Standard lengths: 8 m, 11.8 m

Weight: 17.42 kg/m

Max. tensile strength: 5843 kN/m

 

Product on order only.

PDF Test report

PDF Data sheet

DWG FD180-12

Request this connector

MF230

Steel grade: S355J2

Steel thickness: 12 mm

Standard lengths: 8 m, 11.8 m

Weight M140: 14.77 kg/m

Weight F90: 18.42 kg/m

Max. tensile strength: 2128 kN/m

PDF Data sheet

DWG M140

DWG F90

Request this connector

FD300-12

Steel grade: S355J2

Steel thickness: 12 mm

Standard length: 13.8 m

Weight: 21.4 kg/m

Max. tensile strength: 6312 kN/m

PDF Test report

PDF Data sheet

DWG

Request this connector

MDF310

Steel grade M140: S355J2

Steel grade DF: S430

Steel thickness: 12 mm

Standard lengths: 8 m, 11.8 m

Weight M140: 14.77 kg/m

Weight DF: 14.62 kg/m

Max. tensile strength:

3271 kN/m (FEM)

PDF Data sheet

PDF FEM Simulation

DWG M140

DWG DF

Request this connector

Test report

PDF: Tensile and twist out tests

Connectors

overview 2024

Technical data / disclaimer

SteelWall connectors generally comply with the European standards and are manufactured by certified steel processing companies.

All figures are approximate and may vary. Bar twists are possible up to 2 mm per meter. Tolerance of steel thickness ±1 mm.

Length tolerance up to ±200 mm. Degree details refer to the connector bar axes. Welding base of LPB and FD clutches can be straight or bevelled. We reserve the right to make technical changes. We refer to DIN EN 12063. Please check the sheet pile interlocks with a physical sample section of the desired connector for compatibility.

 

2024-Jan-10. Copyright by SteelWall ISH GmbH. Connectors designed by Richard Heindl.